USAfixTM - Repair Guide (RG) - Master Email RG
- Check the wiring between the terminal block and the solenoid valve
 Level of Difficulty - HIGH  Estimated Completion Time - 15 minutes
TASKI - FG 2C

Tools Required
Tool 
Screwdriver-phillips
Volt meter (True RMS capable)

Parts Required


Step Procedure & Parts & Tools
1 LAY THE MACHINE DOWN WITH THE FRONT COVER FACING UP. REST THE MACHINE ON BOARDS SO THAT THE FILTER ON THE BACK DOESNT GET BROKEN.

2 REMOVE THE 4 SCREWS AND LIFT UP ON THE FRONT COVER TO REMOVE IT.
Screwdriver-phillips

3 REMOVE THE SCREW HOLDING THE TERMINAL BLOCK. REMOVE THE TERMINAL BLOCK FROM THE MACHINE AND PULL THE 2 WIRE CONNECTORS OFF THE SOLENOID VALVE.
Screwdriver-phillips

4 PLACE THE LEAD IN THE TERMINAL BLOCK WHERE THE WIRE IS AND PLACE THE OTHER LEAD IN THE WIRE CONNECTOR AS SHOWN. SET THE VOLT METER TO CONTINUITY. IF THE VOLT METER BEEPS, THE WIRE IS GOOD. REPEAT FOR OTHER WIRE.
Volt meter (True RMS capable)